Electrical
ACS/CCP
For models: D34/E27 - D34/LED. Twilight photoelectric cell. Electronic circuit. Automatic switching on and off (dusk to dawn). 230/240V - 50/60Hz power supply. 16A maximum current. =10.000 cycles working life at max loading. 2 lux minimum switching threshold. Continuous control range from 2 to 100 lux. Excluded-time delay for over-ride switching approximately 30". Temperature range - 30°C + 60°C. Insensitive to transient over-voltage conditions.
D34/CMA
For models D34/E27. Automatic change-over device for stand-by lamp. Automatic change over when operating lamp fails. Automatic reinstatement when failed lamp is replaced. 110/230V ±10% power supply. 50/60Hz frequency. Maximum allowed power at 230V:60W min 75W max. Maximum allowed power at 110V:40W min 60W max. 10 operation working life. Temperature range - 40°C + 60°C. Cable gland entries for Ø7÷12mm cable.
D34/QL4
For models D34/E27. Centralized control panels 4 type sdd. Panel door double lock with key. 230V-50Hz ±10% power supply. Automatic mains switch 16A/10KA-230/400V type C (IEC898). Automatic switching on by CCP twilight cell. Green "mains on" pilot lamp. Contactor maximum load at 230V-2,2KW. Photoelectric cell exclusion and circuit test by bipolar switch 16A-250V. Automatic change-over - CMA system. Red "failed" pilot lamp. Available telealarm for failed lamp and photocell out of service. Connections by single core flexible wires, type N07V-K CEI 20-22 II. Numerical marking. N entries (number of signals) +3 (line-photocell-telealarm) for Ø7÷12mm cable, H07RN-F type.